Rolls-Surrette S6 L16-HC (was S-550)

Call for price

(1 customer review)

Rolls-Surrette S6 L16-HC (previously S-550), 6V deep-cycle flooded lead-acid, 445Ah/20h capacity, group L16, 3 years warranty (minimum order qty.)

SKU: SUR-184-139 Categories: , Tags: , ,

Rolls S6 L16-HC (S-550) lead-acid batteries are considered “new” as long as they are less than 1 year old. Generally this is no issue, even at 1 year of sitting on the shelf they should work fine. All new lead-acid batteries need a handful of cycles to reach full capacity, and those sitting on the shelf for some time are no different. Specific gravity (SG) values of the cells may be quite low when you receive them, and when put in service new batteries should receive an initial full charge, sometimes even an equalize charge. Depending on your charge source(s) it can take many hours before all the cells reach “full” or a SG of 1.265. It is important to take the time and do this!

Rolls Surrette has built a solid reputation over the years as one of the best, if not THE best, sources of deep-cycle batteries for renewable energy systems. Their batteries feature a high cycle life with thick positive battery plates and a large liquid reserve. Surrette batteries are known for their unsurpassed reliability.

The 4000-series batteries are designed specifically for renewable energy applications and come with a solid 3 year full replacement warranty. With good battery care many get 10 to 12 years of service out of these batteries. Our battery care instructions can help get the most out of your batteries.

Adding batteries in series increases the Voltage, while keeping the Amp-hour size the same. Adding batteries in parallel keeps the Voltage the same, while increasing the Amp-hour size of the battery bank. For example, two S6 L16-HC batteries in series makes for a 12 Volt / 445 Ah battery bank. Adding another string of two S6 L16-HC batteries in parallel to these will increase the bank size to 12 Volt / 890 Ah.

Recommended Charge Settings (at 25C)

Charge State 12 Volt 24 Volt 48 Volt
Bulk 15.0 Volt 30.0 Volt 60.0 Volt
Absorb 15.0 Volt 30.0 Volt 60.0 Volt
Float 13.5 Volt 27.0 Volt 54.0 Volt
Equalize 15.8 Volt 31.6 Volt 63.2 Volt
Temperature Compensation: -5 mV/°C/cell

Equalize time: 2.5 hours, add distilled water as-needed halfway through

Absorb time: 0.42 x C / I, where C is the 20-hour battery bank capacity and I is the real-world charge current

For example, a 12 Volt bank of two S6 L16-HC batteries, 445Ah battery bank, with 1000 Watt in solar PV would have a realistic charge current of around 65 Amp in full sun. That makes for an absorb time of 0.42 x 445 / 65 = 2.88 hours = 2 hours 50 minutes

Maximum charge current: 15% of 20-hour battery bank capacity (ie. 0.15 x 445 = 66A for an S6 L16-HC battery for example), never more than 20%

Low-Voltage cut-off: 11.1 / 22.2 / 44.3 Volt (corresponds to about 80% Depth-Of-Discharge)

Features

  • 6 Volt deep-cycle flooded lead-acid
  • 445 Ah at 20 hours, 512 Ah at 100 hours discharge rate
  • BCI group L-16 size, with thick lead alloy flag terminals for 5/16″ bolts
  • Reliable and dependable, designed for off-grid systems
  • Rolls 4000-series battery, Made in Canada!
  • Rope handles for easy carrying
  • Three (3) years warranty

Specifications

Brand

Mnfr. model

,

Battery type

Battery Voltage

Amp-hours (20-hour)

Width

Depth

Height

Weight

Warranty

1 review for Rolls-Surrette S6 L16-HC (was S-550)

  1. Randy Samek

    Good batteries.
    Great place to buy them.

Only logged in customers who have purchased this product may leave a review.

Go to Top